8.6. RS-422/485 Interface of Option, OP-03

The RS-422/485 interface can use command to control the indicator. The interface can read weighing data or parameters or store parameter to the indicator.

The interface can connect max. 32 units and a personal computer in a communication cable.

These unit is specified by address appended to the command.

TS-485 can use 2-wire or 4- wire.

The command and format is the same as the built-in RS-485.

Transmission system

EIA RS-422 / 485,

 

Asynchronous, bi-directional, half-duplex

Data length

7 bis ot 8 bits

Start bit

1 bit

Parity bit

Odd, Even, not used

Stop bits

1 bit, 2 bits

Baud rate

600 bps, 12000 bps, 2400 bps, 4800 bps, 9600 bps, 19200

 

bps, 38400 bps(Jet stream mode)

Line

RS-422: 4 wires

 

RS-485: 2 wires or 4 wires

Connection

Max. 32 units

Character code

ASCII code

Terminator

CR, CR LF

Caution

The option can install either OP-03 or OP-04

Connection

Terminator switch

AD-4402

OP-03 inside

 

SDA

SD

 

SDB

422/485

RDA

TERMINATOR

100Ω

RDB

DE/RE

SG

 

FG

 

 

RD

1SDA

2SDB

3RDA

4RDB

5SG

6FG

FG

Page 88

AD-4402

Page 90
Image 90
A&D PD4000243 manual RS-422/485 Interface of Option, OP-03