Category

 

 

Range

 

address

Name

Descriptions

and

Default

symbol

 

 

choices

 

 

 

0: Off at next start

 

 

 

 

(Turning off until next start)

 

 

 

Batch finish output

1: Off at over or unstable.

 

 

5q f-21

(Turning off when "out of range" or

0 to 2

0

off

 

"unstable condition")

 

 

 

 

 

 

 

 

2: Off at zero band.

 

 

 

 

(Turning off at zero band)

 

 

Category address: [Function] - [Function setting] - [Sequence] - [Timer]

Category

 

 

Range

 

address

Name

Descriptions

and

Default

symbol

 

 

choices

 

 

 

Set the upper limit of the time of

 

 

 

Batch monitoring

sequence.

0 to

0 s

5q f-31

If the sequence is not finnished,

timer

65535 s

 

sequence error SQ.ERR4 is displayed.

 

 

 

If 0 is set, the timer does not work.

 

 

5q f-32

Batch start delay

Set the delay time between start

0.0 to

0.0 s

timer

operation and the flow start

65535 s

 

 

 

Full flow

The timer to prevent weighing error due

0.0 to

0.0 s

5q f-33

comparison

to vibration of open/close operation.

25.5 s

 

interrupt timer

While the timer is not up, the

 

 

 

 

 

Medium flow

 

 

 

comparison does not work.

0.0 to

0.0 s

5q f-34

comparison

 

 

25.5 s

 

interrupt timer

 

 

 

 

 

 

 

Dribble flow

 

0.0 to

0.0 s

5q f-35

comparison

 

 

25.5 s

 

interrupt timer

 

 

 

 

 

 

 

 

Set the time until the dribble flow is can

 

 

 

Drible flow auto-

stant.

0.0 to

3.0 s

5q f-36

Free Fall override

Use to prevent compensation error of

25.5 s

 

time

automatic free fall compensation or

 

 

 

 

 

 

real time free fall compensation.

 

 

 

 

Set the time between closing dribble

0.1to

0.1 s

5q f-37

Eval delay timer

flow and comparing the result. Refer to

25.5 s

 

 

Eval conditions [5q f-13]

 

 

 

 

 

 

Discharge start

Set the time between operating

0.0 to

0.0 s

5q f-38

discharge start and openning the

delay timer

25.5 s

 

discahrge gate

 

 

 

 

 

Page 116

AD-4402

Page 118
Image 118