AD-4402 Page 131
Category address
:
[Function] - [Function setting] - [Option] - [slot
n
] - [OP-07]
OP-07: Option Analog Output
slot
n : slot number
Category
address
symbol Name Descriptions Range
and
choices Default
07 f- 1 Out put data 1: Displayed value
2: Gross value
3: Net value 1 to 3 1
07 f- 2 Weight at 4 mA Set the weighit value when 4 mA is
output. -999999
to
9999999 0
07 f- 3 Weight at 20 mA Set the weighit value when 20 m A is
output. -999999
to