AD-4402 Page 119
Category address
: [Function] - [Function setting] - [Sequence] - [Safety]
Category
address
symbol Name Descriptions Range
and
choices Default
5q f-71 to 5q f-75
The maximum eight inputs for safty check are assigned to the
I/O or OP-05. If an input be inactive, the sequence is stopped
and displays sequence error. Refet to 7.5.11. Err or Messa ge
and Alarm. These safety checks can use during the
sequence.
Bits map
Bit 1: Safety input 1
Bit 2: Safety input 2
Bit 3: Safety input 3
Bit 4: Safety input 4
Bit 5: Safety input 5
Bit 6: Safety input 6
Bit 7: Safety input 7
Bit 8: Safety input 8
0: No (Not used)
1: Yes (Use)
5q f-71 Batching sa fety
check
If the assigned input is inactive during
the weighing sequence, it occurs an
sequence error.
5q f-72 Discharge safety
check
If the assigned input is inactive during
the discharge sequence, it occurs an
sequence error.
5q f-73 Recipe safety
check
If the assigned input is inactive during
the recipe sequence, it occurs an
sequence error.
5q f-74 Mixing sa fety check If the assigned input is inactive during
the mixture sequence, it occurs an
sequence error.
5q f-75 General safety
check
If the assigned input is inactive during
the all sequence, it occurs an sequence
error.
0000000
0
to
1111111
1
00000
000