Page 118 AD-4402
Category address
: [Function] - [Function setting] - [Sequence] - [Setpoint]
Category
address
symbol Name Descriptions Range
and
choices Default
5q f-51 Code recall method
1: Key operation (including s e ri al
interface, field bus)
2: Parallel interface (Digital switch)
3: External switch
1 to 3 1
5q f-53 Hide elements of
material code
Select the parameter to hide of material
code.
Bit 1: Free fall
Bit 2: Preliminary
Bit 3: Optional preliminary
Bit 4: Over
Bit 5: Under
Bit 6: Zero band
Bit 7: Full filling
Bit 8: Tare
Bit 9: Compensation flow open timer
Bit 10: Compensation flow close timer
Bit 11: AF FC range
Bit 12: Dribble supply at entrance
Bit 13: Medium supply at entrance
0: Show
1: Hide
0000000
000000
to
1111111
111111
00000
00000
000
5q f-55 Add Final value and
zero band 0: No (Not added)
1: Yes (Add) 0 to 1 1
5q f-56 Add Final value and
Full value 0: No (Not added)
1: Yes (Add) 0 to 1 1
Category address
: [Function] - [Function setting] - [Sequence] - [Total]
Category
address
symbol Name Descriptions Range
and
choices Default
5q f-61 Automaic material
code total
0: Not totaled automatically
1: Auto-total OK results
To total OK result automatically
2: Auto-total all results
To total all result automatically
0 to 2 0
5q f-62 Automaic recipe
code total 0: No (Not totaled)
1: Yes (Total the result) 0 to 1 0