General Information

Preparing the 85330A to Control the System

Preparing the 85330A to Control the System

Configuring the 85330A is composed of the following steps:

1.Send the 85330A a series of GPIB setup commands prior to starting the run-time sequence.

2.Start the run-time sequence by sending a specific GPIB command.

3.The 85330A then waits for a positioner trigger signal to begin the sequence.

4.The 85330A repeats the sequence for the specified number of frequency points to be measured.

More detailed information on this subject is explained in Chapter 6, “Programming.”

Special Systems

Special system configurations allow you to:

 

Daisy-chain SCUs to provide many channels with a single multiple

 

channel controller.

 

Add remote multiple channel controllers to expand the switch tree or

 

extend the physical distance that switches can be placed from the control

 

room. Additional remote multiple channel controllers can be up to

 

2 Kilometers away from the master.

Switch Components

The 85330A controls the following items:

 

Switch control units

 

In standard systems, the system interface board communicates with one or

 

two SCUs. SCUs perform the following tasks:

 

They decode binary information from the multiple channel controller to

 

determine which switch should be closed.

 

They provide the necessary bias voltages to the switches, which causes

 

them to switch states.

 

In a standard system, one SCU is connected to the multiple channel

 

controller’s PORT 1 connector, and the other SCU is connected to PORT 2.

 

The separate ports provide the ability to put switches at the transmit and

 

receive site.

4-4

85330A Multiple Channel Controller

Page 54
Image 54
Agilent Technologies service manual Preparing the 85330A to Control the System, Special Systems, Switch Components