Agilent Technologies 85330A service manual Output

Models: 85330A

1 166
Download 166 pages 5.42 Kb
Page 106
Image 106

Programming

Programming Examples

1143

OUTPUT

@Hp85330a;”RUNT:TIME:EVEN 0,15000000;”

! 15 sec, 1st point.

1144

OUTPUT

@Hp85330a;”RUNT:TIME:EVEN 1,5000000;”

! 5 sec, 2nd - last point.

1145

OUTPUT

@Hp85330a;”RUNT:TIME:REC 1000000;”

! timeout receiver.

1146

!

 

 

 

 

1147

OUTPUT

@Hp85330a;”RUNT:SWIT:DEL 2;”

 

! Switch settling is 2 uS.

1148

OUTPUT

@Hp85330a;”RUNT:SWIT:SCAN 1,(@”;Switch_start;”:”;Switch_stop;”);”

1149

!

 

 

 

 

1150

OUTPUT

@Hp85330a;”RUNT:SOUR:COUN “;Freq_pts;”;” ! No of frequency points.

1151

OUTPUT

@Hp85330a;”RUNT:SOUR:SOURCE1:TRIG TTL;”

! Set source to ext trig.

1152

OUTPUT

@Hp85330a;”RUNT:SOUR:SOURCE2:TRIG TTL;”

! Set source to ext trig.

1153

!

 

 

 

 

1154

REPEAT

 

 

 

 

1156

OUTPUT @Hp85330a;”SYST:ERR?;”

 

! Check error status

1157

ENTER @Hp85330a;Err_num,Err_str$

 

! until error is 0.

1158

UNTIL Err_num=0

 

 

 

1160

!

 

 

 

 

1161

Set_positioner:!

 

 

 

1162

!

 

 

 

 

1163

! Set positioner to start angle.

 

 

1164

! Set velocity, acceleration.

 

 

1165

! Set start, stop and increment angles.

 

1166

!

 

 

 

 

1167

Start_meas:!

 

 

 

1168

!

 

 

 

 

1169

! Set

the HP 8530A in FAST AUTO-RANGING data mode.

1170

!

 

 

 

 

1171

OUTPUT

@Rec;”FASAD;”

! SET THE RECEIVER TO FAST DATA w/ AUTO-RANGE.

1172

REPEAT

 

! WAIT UNTIL THE RECEIVER IS READY TO

1173

WAIT

.001

! TO TAKE DATA.

 

1174

UNTIL BIT(SPOLL(@Rec),2)

!

 

 

1175

TRIGGER @Rec

! ISSUE HPIB TRIGGER TO BEGIN FAST DATA MODE.

1176

!

 

 

 

 

1177

! Set

the HP 85330A to intitiate the run time control.

1178

!

 

 

 

 

1179

OUTPUT

@Rf;”INIT:CONT ON;”

 

! Initiate the rf source.

1180

OUTPUT

@Lo;”INIT:CONT ON;”

 

! Initiate the lo source.

1181

OUTPUT

@Hp85330a;”RUNT:INIT:IMM;”

! Initiate the HP 85330A run time mode.

1182

!

 

 

 

 

1183

! Set the positioner to take an angle scan.

 

1184

!

 

 

 

 

1185

REM Start the positioner.

 

 

 

1186

!

 

 

 

 

1187

! This

starts the data tranfer from the receiver to the computer. When

1188

! a trigger is issued to the receiver the data is placed into the receiver’s

1189

! buffer and then read from the reciever using the following TRANSFER

1190

! statement.

 

 

 

1191

!

 

 

 

 

1192

TRANSFER @Rec TO @Buffer;RECORDS Points,EOR (COUNT 6)

1193

!

 

 

 

 

6-32

85330A Multiple Channel Controller

Page 106
Image 106
Agilent Technologies 85330A service manual Output