Legacy Analyzer Command List

Table of All Legacy Analyzer Commands

Table 2-1

Alphanumeric List of all Legacy Commands Showing their N9061A Support

 

 

 

 

 

 

 

Command

Description

8566

8568

8560

Page for

 

 

 

 

 

Series

Further

 

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

GDRVSWP

Sweep time for the time

N/A

N/A

N/A

 

 

 

window

 

 

 

 

 

 

 

 

 

 

 

 

GDRVUTIL

Turns the gate utility on or off

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

GDRVVBW

Couple video bandwidth to the

N/A

N/A

N/A

 

 

 

gate length

 

 

 

 

 

 

 

 

 

 

 

 

GETPLOT

Get plot

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

GETPRNT

Get print

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

GL

Gate length

N/A

N/A

Yes

Page 169

 

 

 

 

 

 

 

 

GP

Sets the polarity

N/A

N/A

Yes

Page 170

 

 

(positive/negative) of the gate

 

 

 

 

 

 

trigger

 

 

 

 

 

 

 

 

 

 

 

 

GR

Plot GPIB input as Graphs

No

No

N/A

 

 

 

 

 

 

 

 

 

GRAT

Graticule on/off

Yes

Yes

Yes

Page 171

 

 

 

 

 

 

 

 

HAVE

Checks for options installed

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

HD

Holds data entry

No

No

No

Page 172

 

 

 

 

 

 

 

 

HN

Harmonic number

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

HNLOCK

Harmonic lock

No

N/A

No

 

 

 

 

 

 

 

 

 

HNUNLK

Harmonic band unlock

No

N/A

No

 

 

 

 

 

 

 

 

 

I1

Sets the RF coupling to AC

N/A

Yes

N/A

Page 173

 

 

 

 

 

 

 

 

I2

Sets the RF coupling to DC

N/A

Yes

N/A

Page 175

 

 

 

 

 

 

 

 

IB

Input to trace B memory

No

No

N/A

 

 

 

 

 

 

 

 

 

ID

Instrument identification

Yes

Yes

Yes

Page 177

 

 

 

 

 

 

 

 

IDCF

Identified signal to center

N/A

N/A

No

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

IDFREQ

Identified signal frequency

N/A

N/A

No

 

 

 

 

 

 

 

 

 

IDSTAT

Signal identifier status

No

N/A

N/A

 

 

 

 

 

 

 

 

 

IF

Conditional Programming

No

No

No

 

 

 

(If…then…else…endif)

 

 

 

 

 

 

 

 

 

 

 

 

IFTKNL

16 bit discrete fourier transform

No

No

N/A

 

 

 

 

 

 

 

 

 

INT

Integer

No

No

No

 

 

 

 

 

 

 

 

 

INZ

Input impedance

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

51

Page 51
Image 51
Agilent Technologies N9030a manual Gdrvswp

N9030a specifications

Agilent Technologies, now known as Keysight Technologies, is recognized as a leader in providing advanced electronic measurement solutions. One of their highlighted products is the N9030A PXA X-Series Signal Analyser, a versatile instrument that caters to the needs of engineers and researchers in various fields, including telecommunications, aerospace, and defense.

The Agilent N9030A is designed to address the increasing complexity of modern signals. One of its standout features is its exceptional frequency range, spanning from 3 Hz to 50 GHz, making it suitable for both wideband and narrowband applications. This broad frequency coverage allows users to capture a wide array of signals, from low-frequency analog to high-frequency digital communications.

Another significant characteristic of the N9030A is its high dynamic range, which enables accurate measurements even in the presence of strong interfering signals. This capability is essential for testing and developing communication systems that operate in challenging environments, where signal integrity is paramount. The analyser also features a high sample rate of 5 GS/s, providing detailed resolution for even the most intricate signals.

The integrated measurement applications further enhance the instrument’s versatility, allowing for specific analyses related to modulation formats, spectral emissions, and time-domain events. Such applications streamline workflows and improve measurement efficiency, making it easier for users to obtain and interpret data.

One of the technological highlights of the N9030A is its advanced digital signal processing (DSP), which significantly improves measurement speed and performance. The DSP capabilities allow engineers to conduct real-time analysis, which is critical for applications that require immediate feedback, such as signal troubleshooting and validation.

The user-friendly interface of the N9030A, along with a myriad of connectivity options, ensures that integration into existing testing setups is seamless. Data can be easily exported to other software tools for further analysis, enhancing collaboration and report generation.

In conclusion, the Agilent N9030A PXA X-Series Signal Analyser stands out as a powerful tool for modern signal analysis. With its wide frequency range, high dynamic range, advanced DSP capabilities, and integrated measurement applications, it is tailored to meet the rigorous demands of today’s engineers and researchers. Whether for development, testing, or troubleshooting, the N9030A provides the performance and flexibility required for successful project outcomes.