FOFFSET Frequency Offset

FOFFSET

Frequency Offset

Syntax

FOFFSET SP

SP

?

Table 4-10

real

UP

DN

OA

HZ

KHZ

MHZ

GHZ

KZ

MZ

GZ

;

LF

CR

SP

,

Item

Description/Default

Range

 

 

 

REAL

Any real or integer number.

 

 

Default unit is Hz.

 

 

 

 

Preset State: 0 Hz

Legacy Products

8560 series, 8566A/B, 8568A/B

Description

The FOFFSET command selects a value that offsets the frequency scale for all absolute frequency readouts (for example, center frequency). Relative values such as span and marker delta are not offset.

When an offset is in effect, it is displayed beneath the bottom graticule line on the analyzer screen.

Execute “FOFFSET 0;” or “IP;” to turn off the offset.