Legacy Analyzer Command List

Table of All Legacy Analyzer Commands

Table 2-1

Alphanumeric List of all Legacy Commands Showing their N9061A Support

 

 

 

 

 

 

 

Command

Description

8566

8568

8560

Page for

 

 

 

 

 

Series

Further

 

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

LIMIFT

Select frequency or time limit

N/A

N/A

N/A

 

 

 

line

 

 

 

 

 

 

 

 

 

 

 

 

LIMIHI

Upper limit

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

LIMILINE

Limit line

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

LIMILO

Lower limit

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

LIMIMIRROR

Mirror limit line

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

LIMIMODE

Limit line entry mode

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

LIMIPURGE

Disposes of current limit line,

N/A

N/A

Yes

Page 221

 

 

not limit line table

 

 

 

 

 

 

 

 

 

 

 

 

LIMIRCL

Load stored limit line into limit

N/A

N/A

No

 

 

 

line table

 

 

 

 

 

 

 

 

 

 

 

 

LIMIREL

Determine whether limit line

N/A

N/A

Yes

Page 222

 

 

values absolute/relative

 

 

 

 

 

 

 

 

 

 

 

 

LIMISAV

Save contents of limit line table

N/A

N/A

No

 

 

 

for recall

 

 

 

 

 

 

 

 

 

 

 

 

LIMISEG

Define slope & offset of limit

N/A

N/A

N/A

 

 

 

line segments

 

 

 

 

 

 

 

 

 

 

 

 

LIMISEGT

Enter limit line segment for

N/A

N/A

N/A

 

 

 

sweep time

 

 

 

 

 

 

 

 

 

 

 

 

LIMITEST

Compare active trace data to

N/A

N/A

Yes

 

 

 

limit line parameters

 

 

 

 

 

 

 

 

 

 

 

 

LIML

Amplitude value for limit line

N/A

N/A

Yes

Page 223

 

 

segment in lower limit line

 

 

 

 

 

 

 

 

 

 

 

 

LIMM

Middle amplitude value for

N/A

N/A

Yes

 

 

 

limit-line segment

 

 

 

 

 

 

 

 

 

 

 

 

LIMTFL

Specifies a flat limit-line

N/A

N/A

No

 

 

 

segment

 

 

 

 

 

 

 

 

 

 

 

 

LIMTSL

Specifies a sloped limit-line

N/A

N/A

Yes

Page 224

 

 

segment

 

 

 

 

 

 

 

 

 

 

 

 

LIMU

Amplitude value for limit line

N/A

N/A

Yes

Page 225

 

 

segment in upper limit line

 

 

 

 

 

 

 

 

 

 

 

 

LINFILL

Line fill

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

LL

Provides lower left recorder

No

No

N/A

 

 

 

output voltage at rear

 

 

 

 

 

 

 

 

 

 

 

 

56

Page 56
Image 56
Agilent Technologies N9030a manual Limift

N9030a specifications

Agilent Technologies, now known as Keysight Technologies, is recognized as a leader in providing advanced electronic measurement solutions. One of their highlighted products is the N9030A PXA X-Series Signal Analyser, a versatile instrument that caters to the needs of engineers and researchers in various fields, including telecommunications, aerospace, and defense.

The Agilent N9030A is designed to address the increasing complexity of modern signals. One of its standout features is its exceptional frequency range, spanning from 3 Hz to 50 GHz, making it suitable for both wideband and narrowband applications. This broad frequency coverage allows users to capture a wide array of signals, from low-frequency analog to high-frequency digital communications.

Another significant characteristic of the N9030A is its high dynamic range, which enables accurate measurements even in the presence of strong interfering signals. This capability is essential for testing and developing communication systems that operate in challenging environments, where signal integrity is paramount. The analyser also features a high sample rate of 5 GS/s, providing detailed resolution for even the most intricate signals.

The integrated measurement applications further enhance the instrument’s versatility, allowing for specific analyses related to modulation formats, spectral emissions, and time-domain events. Such applications streamline workflows and improve measurement efficiency, making it easier for users to obtain and interpret data.

One of the technological highlights of the N9030A is its advanced digital signal processing (DSP), which significantly improves measurement speed and performance. The DSP capabilities allow engineers to conduct real-time analysis, which is critical for applications that require immediate feedback, such as signal troubleshooting and validation.

The user-friendly interface of the N9030A, along with a myriad of connectivity options, ensures that integration into existing testing setups is seamless. Data can be easily exported to other software tools for further analysis, enhancing collaboration and report generation.

In conclusion, the Agilent N9030A PXA X-Series Signal Analyser stands out as a powerful tool for modern signal analysis. With its wide frequency range, high dynamic range, advanced DSP capabilities, and integrated measurement applications, it is tailored to meet the rigorous demands of today’s engineers and researchers. Whether for development, testing, or troubleshooting, the N9030A provides the performance and flexibility required for successful project outcomes.