Legacy Analyzer Command List

Table of All Legacy Analyzer Commands

Table of All Legacy Analyzer Commands

The following table lists all of the original programming commands from the legacy analyzers (that is, the 8566A/B, the 8568A/B, and the 8560 Series), and indicates which are supported in N9061A. Refer to the alphabetical listing of commands in Chapter 4 , “Programming Commands,” on page 75 for more detailed information about each supported command.

Table 2-1

Alphanumeric List of all Legacy Commands Showing their N9061A Support

 

 

 

 

 

 

 

Command

Description

8566

8568

8560

Page for

 

 

 

 

 

Series

Further

 

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

A1

Clear-writes trace A

Yes

Yes

Yes

Page 79

 

 

 

 

 

 

 

 

A2

Max Holds trace A

Yes

Yes

Yes

Page 80

 

 

 

 

 

 

 

 

A3

View trace A

Yes

Yes

Yes

Page 81

 

 

 

 

 

 

 

 

A4

Blanks trace A

Yes

Yes

Yes

Page 82

 

 

 

 

 

 

 

 

ABORT

Interrupt operation of all

N/A

N/A

No

 

 

 

user-defined functions

 

 

 

 

 

 

 

 

 

 

 

 

ABS

Absolute

No

No

No

 

 

 

 

 

 

 

 

 

ACP

Performs the adjacent channel

N/A

N/A

N/A

 

 

 

power measurement

 

 

 

 

 

 

 

 

 

 

 

 

ACPACCL

Accelerate adjacent channel

N/A

N/A

No

 

 

 

power measurement

 

 

 

 

 

 

 

 

 

 

 

 

ACPALPHA

Adjacent channel power alpha

N/A

N/A

Yes

Page 83

 

 

weighting

 

 

 

 

 

 

 

 

 

 

 

 

ACPALTCH

Adjacent channel power

N/A

N/A

Yes

Page 84

 

 

alternate channels

 

 

 

 

 

 

 

 

 

 

 

 

ACPBRPER

Adjacent channel power burst

N/A

N/A

Yes

Page 85

 

 

period

 

 

 

 

 

 

 

 

 

 

 

 

ACPBRWID

Adjacent channel power burst

N/A

N/A

Yes

Page 86

 

 

width

 

 

 

 

 

 

 

 

 

 

 

 

ACPBW

Specifies channel bandwidth for

N/A

N/A

Yes

Page 87

 

 

ACP measurement

 

 

 

 

 

 

 

 

 

 

 

 

ACPCOMPUTE

Compute adjacent channel

N/A

N/A

Yes

Page 88

 

 

power

 

 

 

 

 

 

 

 

 

 

 

 

ACPCONTM

Performs ACP measurement in

N/A

N/A

N/A

 

 

 

continuous sweep

 

 

 

 

 

 

 

 

 

 

 

 

ACPE

Adjacent channel power

N/A

N/A

N/A

 

 

 

extended

 

 

 

 

 

 

 

 

 

 

 

 

42

Page 42
Image 42
Agilent Technologies N9030a manual Table of All Legacy Analyzer Commands

N9030a specifications

Agilent Technologies, now known as Keysight Technologies, is recognized as a leader in providing advanced electronic measurement solutions. One of their highlighted products is the N9030A PXA X-Series Signal Analyser, a versatile instrument that caters to the needs of engineers and researchers in various fields, including telecommunications, aerospace, and defense.

The Agilent N9030A is designed to address the increasing complexity of modern signals. One of its standout features is its exceptional frequency range, spanning from 3 Hz to 50 GHz, making it suitable for both wideband and narrowband applications. This broad frequency coverage allows users to capture a wide array of signals, from low-frequency analog to high-frequency digital communications.

Another significant characteristic of the N9030A is its high dynamic range, which enables accurate measurements even in the presence of strong interfering signals. This capability is essential for testing and developing communication systems that operate in challenging environments, where signal integrity is paramount. The analyser also features a high sample rate of 5 GS/s, providing detailed resolution for even the most intricate signals.

The integrated measurement applications further enhance the instrument’s versatility, allowing for specific analyses related to modulation formats, spectral emissions, and time-domain events. Such applications streamline workflows and improve measurement efficiency, making it easier for users to obtain and interpret data.

One of the technological highlights of the N9030A is its advanced digital signal processing (DSP), which significantly improves measurement speed and performance. The DSP capabilities allow engineers to conduct real-time analysis, which is critical for applications that require immediate feedback, such as signal troubleshooting and validation.

The user-friendly interface of the N9030A, along with a myriad of connectivity options, ensures that integration into existing testing setups is seamless. Data can be easily exported to other software tools for further analysis, enhancing collaboration and report generation.

In conclusion, the Agilent N9030A PXA X-Series Signal Analyser stands out as a powerful tool for modern signal analysis. With its wide frequency range, high dynamic range, advanced DSP capabilities, and integrated measurement applications, it is tailored to meet the rigorous demands of today’s engineers and researchers. Whether for development, testing, or troubleshooting, the N9030A provides the performance and flexibility required for successful project outcomes.