![](/images/new-backgrounds/1033321/33321561x1.webp)
Programming Commands
OL Output Learn String
OL
Output Learn String
Syntax
OL | SP | 80 byte binary | |
string | |||
|
|
?
;
Legacy Products
8566A/B, 8568A/B
Description
The OL command transmits information to the controller that describes the state of the analyzer when the OL command is executed. This information is called the “learn string.” The learn string can be sent from the controller memory back to the analyzer to restore the analyzer to its original state.
NOTE | The OL command is not completely supported, due to differences between the |
| |
| the bits supported within that byte. |
|
|
Byte | Support Information |
|
|
1 | Fixed decimal value 31 |
|
|
2 | Fixed decimal value 118 |
|
|
3 to 9 | Supported |
|
|
10 | Supported |
|
|
11 | Unsupported: Fixed decimal 0 |
|
|
12 to 17 | Supported |
|
|
18 | Supported: Bits 6, 2, 1 and 0 |
| Unsupported: Bits 7, 5, 4, and 3 |
|
|