Legacy Analyzer Command List

Table of All Legacy Analyzer Commands

Table 2-1

Alphanumeric List of all Legacy Commands Showing their N9061A Support

 

 

 

 

 

 

 

Command

Description

8566

8568

8560

Page for

 

 

 

 

 

Series

Further

 

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

MERGE

Merge two traces

No

No

N/A

 

 

 

 

 

 

 

 

 

MF

Returns frequency of the active

Yes

Yes

Yes

Page 238

 

 

marker

 

 

 

 

 

 

 

 

 

 

 

 

MIN

Minimum

No

No

No

 

 

 

 

 

 

 

 

 

MINH

Min Hold

N/A

N/A

Yes

Page 239

 

 

 

 

 

 

 

 

MINPOS

Returns the minimum position

Yes

Yes

N/A

Page 240

 

 

in the trace

 

 

 

 

 

 

 

 

 

 

 

 

MIRROR

Mirror image of the trace

No

No

N/A

 

 

 

 

 

 

 

 

 

MKA

Amplitude of the active marker

Yes

Yes

Yes

Page 241

 

 

 

 

 

 

 

 

MKACT

Specifies the active marker

Yes

Yes

N/A

Page 242

 

 

 

 

 

 

 

 

MKACTV

Marker as the active function

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

MKBW

Marker bandwidth

N/A

N/A

Yes

Page 243

 

 

 

 

 

 

 

 

MKCF

Moves the active marker to

Yes

Yes

Yes

Page 244

 

 

center frequency

 

 

 

 

 

 

 

 

 

 

 

 

MKCHEDGE

Marker to channel edge

N/A

N/A

No

 

 

 

 

 

 

 

 

 

MKCONT

Continues sweeping from the

No

No

N/A

 

 

 

marker after stop

 

 

 

 

 

 

 

 

 

 

 

 

MKD

Delta marker

Yes

Yes

Yes

Page 245

 

 

 

 

 

 

 

 

MKDELCHBW

Delta markers to channel power

N/A

N/A

No

 

 

 

bandwidth

 

 

 

 

 

 

 

 

 

 

 

 

MKDLMODE

Marker delta display line mode

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

MKDR

Reciprocal of marker delta

N/A

N/A

No

 

 

 

 

 

 

 

 

 

MKF

Specifies the frequency of the

Yes

Yes

Yes

Page 246

 

 

active marker

 

 

 

 

 

 

 

 

 

 

 

 

MKFC

Turns the marker frequency

N/A

Yes

Yes

Page 247

 

 

counter on or off

 

 

 

 

 

 

 

 

 

 

 

 

MKFCR

Specifies the marker frequency

N/A

Yes

Yes

Page 248

 

 

counter resolution

 

 

 

 

 

 

 

 

 

 

 

 

MKMCF

Marker mean to center

N/A

N/A

No

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

MKMIN

Moves active marker to

Yes

Yes

Yes

Page 250

 

 

minimum signal detected

 

 

 

 

 

 

 

 

 

 

 

 