Configuring the Diagnostic Test Environment
Page 36-17

Configuring Tests for Ethernet Modules

Tailoring of applicable Ethernet modules includes selection of Port Speeds and of Port Modes.
To configure applicable diagnostic tests for an Ethernet 10/100 switching module in slot 3,
enter:
testcfg 3
The following is a sample display of the test configuration for an Ethernet 10/100 switching
module.
Test Configuration for slot 3
1) Skip this slot during test { No (1),
Yes (2) } : No
2) Port Speed { 10/100 (1),
100 (2),
10 (3) } : 10/100
3) Port Mode { Full Duplex (1),
Half Duplex (2) } : Full Duplex
Enter (option=value/save/cancel) :
To change any of the values above, enter the line number, followed by an equal sign, and
followed by the new value. For example, to change the Port Mode field to half duplex, enter
3=2
The configurable fields displayed by the testcfg command for an Ethernet module are
described below.
Skip this slot during test. Allows the user to select to bypass this slot when the test all command
is issued. The default is No.
Port Speed. Allows the user to select module port speed during the diagnostic port test. Selec-
tion includes 10/100BaseT, 100BaseT, or 10BaseT. The default is 10/100BaseT, which alternates
the speed of the port test from 10 to 100 on each pass of the port test.
Port Mode. Allows the user to select module port mode during diagnostic port test. Selection
includes Full Duplex or Half Duplex. The default value is Full Duplex.
Enter save if you want to make this change. If you want to cancel this change, enter cancel
and the testcfg command will terminate.