Running Diagnostics on an Entire Chassis
Page 36-21
2) Stop on Failure
Enter 2 to halt diagnostics in an active state when a failure occurs or 1 (the default) to exit
diagnostics and display the Test Summation and Failure Summation sections of the test
command output. Setting this field to 2 can be used to further troubleshoot problems.
However, setting this field to 2 requires more user intervention during a test.
3) Port Test Bypass
Enter 2 to complete testing of all ports regardless of port test failures or 1 (the default) to stop
testing at the first port failure. Setting this field to 2 can be used to further troubleshoot prob-
lems.
4) Port Test Type
Enter 1 (the default) for a port test, 2 for an Internal Loopback (ILB) test, 3 for a stress test, or
4 for an ILB stress test. External cables are required for the port and stress tests but not for the
ILB test. In addition, the stress test requires a special image file (see Running Diagnostics on
page 36-2) and is only available for Ethernet (ESX and GSX) modules on the Omni
Switch/Router.
Note
Option 5, HRE-X Test Mode, is for the Omni
Switch/Router only.
5) HRE-X Test Mode
This option lets you configure port tests for HRE-Xs installed on Omni Switch/Router switch-
ing modules. It does not affect the port test for HRE-Xs installed on MPXs. Currently, the port
test on HRE-Xs installed on switching modules runs in conjunction with the normal port test.
Each physical port is tested with the normal port test path and then through the HRE-X port
test path before testing the next physical port. Subsequent physical ports are tested with only
the normal port test path.
Enter 1 to bypass testing of the HRE-X when the port test is run or 2 to perform the test as
described above.