Configuring Kodiak Ethernet Ports
Page 15-7

Configuring Kodiak Ethernet Ports

The 10/100cfg command allows you to configure the link mode (full or half-duplex) for ports
on newer Kodiak Ethernet modules.
This procedure describes how to configure Ethernet modules on the Omni Switch/Router.
Follow these steps to configure a Kodiak Ethernet port:
1. Enter 10/100cfg at the system prompt and press <Enter>.
2. The system displays a prompt asking for the slot and port number:
Enter Slot/Interface :
Enter the slot number, a slash (/), and the port number of the Ethernet port that you want
to configure. Press <Enter>.
3. The following prompt displays, showing the current link mode:
Link Mode [Full, Half] (Currently (H)alf Duplex) :
Enter F to set the port to full-duplex mode or H to set the port to half-duplex mode. In
full-duplex mode, the full 100 or 10 Mbps of bandwidth is used for data traveling on each
direction of the cable. Press <Enter> after you enter the Mode. The new mode will take
effect; no reboot is required.