Trap Tables

Page 13-63
Trap Type fddiLerFlagChange
Object ID 1.3.6.1.4.1.800.3.1.1.1.0.65
Description The LER (Link Error Rate) flag on a port changed from CLEAR to SET.
Bit Position
(Word 3)

0

Hex Value
(Word 3)
1
Trap Text
and
Variable
Descrip-
tions
FDDI: Link Error Rate on a port is set (SMTIndex 1, port 2, LerFlag 3)
LER Flag. The condition becomes
active when the value of the
fddiPRTLerEstimate is less than or
equal to fddimibPORTLerEstimate.
The following integers are valid
values:
1 True
2 False
SMT Index. A unique value for
each SMT (Station Management).
The value for each SMT must
remain constant at least from
one re-initialization of the enti-
ty’s network management sys-
tem to the next re-initialization.
Port index. A unique value for each port
with in a given SMT, which is the same
as the corresponding resource index in
SMT. The value for each port must
remain constant at least from one re-ini-
tialization of the entity’s network man-
agement system to the next re-