General User Interface Guidelines
Page 4-24

Configuring the Auto Logout Time

When the switch detects no user activity on the UI for a certain period of time, it automati-
cally logs the user out of the system. By default, this automatic logout occurs after 4 minutes
of console inactivity. You can configure the automatic logout to range from 1 minute to
35,791,394 minutes.
To set a new automatic logout time, type uic at the user prompt and press <Enter>.
A screen similar to the following will be displayed.
UI Configuration
1) Prompt : ‘$Menu-Path% ’
2) More : off
21) Lines : 22 lines
3) Verbose : off
4) Timeout : 5 minutes
Command {Item=Value/?/Help?Quit?Redraw?Save} (Redraw) :
Next, type 4=on, followed by the desired automatic logout time, and press <Enter>. For exam-
ple:
4=15.
After you press <Enter>, the screen will be redrawn. Note that the automatic logout time at
line 4 of the uic submenu has been changed.
UI Configuration
1) Prompt : ‘$Menu-Path% ’
2) More : on
21) Lines : 22 lines
3) Verbose : off
4) Timeout : 15 minutes
Command {Item=Value/?/Help?Quit?Redraw?Save} (Redraw) :
Be sure to type save at the submenu prompt and press <Enter>. The automatic logout time
has been successfully changed.
Note
The automatic logout value you enter takes effect
immediately; you do not have to reboot the switch. In
addition, the timeout parameter you enter is saved.
Later sessions using this account will have the same
automatic logout parameter until you change it.