OmniChannel
Page 15-15
3. A screen similar to the following displays:
Displaying channel 2
Channel Id Phy. Port Port Status Mac Count
=====================================================================
2 5/6 Inactive 0
5/7 Inactive 0
3 5/3 Active 35
5/4 Active 34
5/5 Active 34
The following sections describe the variables in this table.
Channel Id. The identification number assigned to this OmniChannel during the crechnl
configuration procedure.
Phy. Port. The physical slot and port number for all ports included in the OmniChannel.
The slot number is listed first, then a slash (/), and the port number on the Ethernet
module.
Port Status. The current operational status of this physical port. If the port is Active, then a
cable is connected and data is capable of passing to and from the port. If the port is Inac-
tive, then a cable may not be attached or the port is inoperational for hardware or soft-
ware reasons.
Mac Count. The current number of MAC addresses that have been learned on this port. A
separate MAC count is given for each physical port in the OmniChannel.