Trap Tables
Page 13-40
Trap moduleResetReload
Object ID 1.3.6.1.4.1.800.3.1.1.4.0.17
Description The specified module has been either reset or reloaded. A reload may

occur during a firmware download.

Bit Position
(Word 1)
16
Hex Value
(Word 1)
1 0000
Trap Text
and
Variable
Descrip-
tions
Module reset or reloaded by chassis manager (slot 4 subunit 1 type 6 status 3)
Module Type. Indicates the module type that was reset or
reloaded. The following integers are valid values:
Submodule Type. Indicates the submodule that was reset or reloaded.
Typically this value will be 1, meaning the base module was reset or
reloaded. If this value is 2, then HSX module 1 was affected. If this
value is 3, then HSX module 2 was affected.
Operational State. Indicates the current state of the module that was reset or reload-
ed. The following integers are valid values:
1 Unknown state. The module may have failed low-level self-test.
2 Invalid. The module may exist, by the chassis does not have control of it.
3 Operational. The module is running fine with no errors.
4 Disabled. The module has been set to disable through the UI or SNMP.
5 Reset. The module has been reset.
6 Loading. The module is in the middle of loading.
7 Testing. The module is in self-test.
8 Warning. A warning was detected during operation.
9 Non-fatal error. A non-fatal error was detected during operation.
10 Fatal error. A fatal error occurred during operation. The module may or may
not be functional.
13 ESM 12-port 10BASE-T
14 ESM 6-port universal module
15 MPM version II
16 ATM DS-3
17 FSM FDDI single mode
18 ASM .5 MB single mode
19 ASM UTP
20 ESM 8-port fiber
21 ESM 12-port Telco
22 TSM fiber
23 ASM 2 MB multi-mode
24 ASM 2 MB single mode
4 HSM
5 MPM
6 ESM 8-port 10BASE-T
7 ESM 16-port
8 TSM 6-port UTP/STP
9 FSM FDDI module
10 FSM CDDI module
11 ESM 4-port
12 ASM .5 MB multi-mode
.Slot number. The slot number of the
module that was reset or reloaded.