Group 300 Cable Connection

The DEFINITY LAN Gateway does not use this connection.

LAN Connection

Make the following connections:

A 10BaseT twisted pair cable with a male RJ-45 connector must be present at the wall field, no further than 25 feet from the back of the switch where DEFINITY LAN Gateway resides. The customer is responsible for this LAN connection.

A 104A connecting block will be mounted on the wall within reach of this connector. This is supplied by AT&T. Eight wires must be hard-connected across the two mounting blocks inside the 104A prior to mounting it to the wall, as shown in Figure 2-7, 104A Mounting Block. The ends of each wire are stripped of insulation. A punch-down tool is used to press the ends of these eight wires into the mounting blocks. Four protector caps snap over the top of the mounting blocks.

NOTE:

AT&T service technicians dispatched for DEFINITY LAN Gateway system installation and maintenance may not troubleshoot the customer LAN. The demarcation point for the DEFINITY LAN Gateway LAN is the point of connection into the connecting block where the cord plugs in. The customer is responsible for the following: the LAN cable, the connector at the end of the cable for connection into the DEFINITY LAN Gateway system, and LAN administration not performed by AT&T on the DEFINITY LAN Gateway system. After cutover, the customer is also responsible for maintaining the TCP/IP addresses and administration on the DEFINITY LAN Gateway system unless otherwise specified by contract.

Issue 1 January 1996 2-15

Page 34
Image 34
AT&T 555-230-223 manual Group 300 Cable Connection, LAN Connection