Appendix F: Returning the

F

Application to its Original State

This appendix details how to return the system to its original state if it should crash.

1.Make sure the administrative/maintenance terminal is physically connected to Main/Port A on the TN2208.

2.Insert the original DEFINITY LAN Gateway tape that came with the system into the system assembly and close the lever.

3.Press the BACK, NEXT/NO, and ENTER/YES buttons on the faceplate of the TN2208 simultaneously. Hold them down until the LCD displays a line of stars.

4.When the stars disappear, the terminal screen displays a message such as the following:

MFB 386FW Version: AU00S07F0

Local Console: Output ON, Input OFF

Remote Maintenance Console: INACTIVE

-> FAC Reset - FAC 3 Button

5. Press CTRL C twice in quick succession.

The following prompt appears: command menu:

6.Type 7 and press Return . The following prompt appears:

Auto Boot Preempted

Enter 1 for Disk, 2 for Tape (Default=Disk):