CHAPTER 4 IMAGE FORMATION SYSTEM

Reference:

The fluorescent lamp heater will not operate unless the copier’s heater switch is

turned on.

3. Detaching the Blank Exposure Assembly

1)Open the front cover.

2)Pull the copier’s open/close lever to open the copier.

3)Detach the inside cover.

4)Detach the exhaust fan and Drum cartridge. (See “Detaching the Exhaust Fan”.)

5)Disconnect the connector q (J315) on the DC controller PCB, and remove the two screws w.

q

w

Figure 4-308

6)Push up the blank exposure assembly e lightly upward, and pull it out toward the bottom front.

e

Figure 4-309

4-34

COPYRIGHT © 1997 CANON INC.

CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)

Page 110
Image 110
Canon NP6218, FY8-13EX-000 service manual Reference, Detaching the Blank Exposure Assembly