CHAPTER 10 TROUBLESHOOTING

4. After Replacing the Drum Unit

Whenever you have replaced the drum unit, enter the date of replacement and the current counter reading on the label (Figure 10-226) that came with the drum unit; attach the label to the front cover of the new drum unit, and perform the image basic adjustment procedure.

Figure 10-226

5. Attaching the Drum Heater

1)Detach the front cover.

2)Open the copier’s top body by operating the copier open/close lever.

3)Remove the two fixing screws w, and detach the harness cover q.

Figure 10-227

4)Detach the transfer roller and the static eliminator.

5)Detach the transfer guide.

6)Butt the two heaters against the transfer guide as shown in Figure 10-228, and fix the two mounts with two screws e; further, fix the harness in place using two harness bands r (front, rear).

Figure 10-228