CHAPTER 10 TROUBLESHOOTING

2.

E001

 

 

 

 

 

 

 

 

 

 

 

Cause

Step

Checks

Results

Action

 

 

 

 

 

Thermistor

1

Disconnect the connector (J4) of

YES

Replace the fixing upper

 

 

 

the fixing heater, and press the

 

unit.

 

 

 

power switch while holding down

 

 

 

 

 

the service mode switch. (This

 

 

 

 

 

clears E001; about 2 sec later,

 

 

 

 

 

the power switch turns off

 

 

 

 

 

automatically.) Let the fixing

 

 

 

 

 

assembly cool sufficiently; then,

 

 

 

 

 

disconnect J4. Is the resistance

 

 

 

 

 

between J47-1 and -2 about 0

 

 

 

 

 

and the resistance between J47-3

 

 

 

 

 

and-4 about 0 ?

 

 

 

 

 

 

 

Fixing heater

2

Replace the fixing heater driver

YES

End.

driver PCB

 

PCB. Is the problem corrected?

 

 

DC controller

 

 

NO

Replace the DC

PCB

 

 

 

controller PCB.

 

 

 

 

 

 

3.

E002, E003

 

 

 

 

 

 

 

 

 

 

 

Cause

Step

Checks

Results

Action

 

 

1 Disconnect the connector (J4) of

YES

See the descriptions

 

 

 

the fixing heater, and press the

 

under “E000.”

 

 

 

power switch while pressing the

 

 

 

 

 

service mode switch. (This clears

 

 

 

 

 

the E code; about 2 sec later, the

 

 

 

 

 

power switch turns off

 

 

 

 

 

automatically.) Turn on the power

 

 

 

 

 

switch; is E000 indicated?

 

 

Wiring

2 Is the wiring between J304 and

NO

Correct the wiring.

 

 

 

J47 on the DC controller PCB

 

 

 

 

 

proper?

 

 

DC controller

3 Replace the DC controller PCB. Is

YES

End.

PCB

 

the problem corrected?

 

 

Fixing heater

 

 

NO

Replace the fixing heater

driver PCB

 

 

 

driver PCB.

 

 

 

 

 

 

10-64

COPYRIGHT © 1997 CANON INC.

CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)

Page 328
Image 328
Canon NP6218, FY8-13EX-000 service manual E001, E002, E003, 10-64