CHAPTER 10 TROUBLESHOOTING

No.

Description

Settings

 

Remarks

 

 

 

 

320

Arch adjustment when cassette

0 ~ 63

A higher setting increases the arch.

 

2 is used (pick-up roller OFF

 

default:

25

 

timing)

 

unit:

0.27 mm

 

 

 

 

321

Arch adjustment when cassette

0 ~ 63

A higher setting increases the arch.

 

2 is used (pick-up roller OFF

 

default:

25

 

timing)

 

unit:

0.27 mm

 

 

 

 

322

Arch adjustment when cassette

0 ~ 63

A higher setting increases the arch.

 

2 is used (pick-up roller OFF

 

default:

25

 

timing)

 

unit:

0.27 mm

 

 

 

 

323

Pick-up clutch (CL2) off timing

0 ~ 63

For factory only

 

adjustment

 

default:

32

 

 

 

 

324

Cassette 2 pick-up clutch

0 ~ 63

For factory only

 

(CL1cu) off timing adjustment

 

default:

20

 

 

 

 

325

Cassette 3 pick-up clutch

0 ~ 63

For factory only

 

(CL2cu) off timing adjustment

 

default:

20

 

 

 

 

326

Scanning lamp intensity

0 ~ 76

For factory only

 

adjustment

 

default:

75

 

 

 

 

 

Table 10-15-2

10-104

COPYRIGHT © 1997 CANON INC.

CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)