CHAPTER 10 TROUBLESHOOTING

No.

Description

Settings

 

 

Remarks

 

 

 

 

 

 

311

Left/right margin adjustment

0 ~ 15

A higher setting increases the

 

(Direct; home position for slide

 

margin on both left and right.

 

shutter for blank exposure)

 

default:

8

 

 

 

 

 

 

 

unit:

0.27 mm

 

 

 

 

 

 

 

312

Left/right margin adjustment

-10 ~ +10

A higher setting increases the

 

(Reduce; travel distance of slide

 

margin on both left and right.

 

shutter for blank exposure)

 

default:

0

 

 

 

 

 

 

 

unit:

0.27 mm

 

 

 

 

 

 

 

313

Primary output voltage correction

-16 ~ +16

Enter the setting recorded on the label

 

(corrects output voltage

 

after replacing the drum cartridge.

 

determined by APVC)

 

 

 

 

 

 

 

 

 

 

 

314

APVC measured current shift

-40 ~ +40

Enter the setting recorded on the label

 

(corrects the results of APVC)

 

after replacing the drum cartridge.

 

 

 

 

 

 

 

 

 

315

Voltage correction for

-16 ~ +16

default:

0

 

 

 

 

 

measurement in APVC (corrects

 

unit:

16 V

 

 

 

 

voltage for measurement applied

 

Enter the value recorded on the label

 

at time of APVC)

 

on the composite power supply when

 

 

 

replacing the composite power supply.

 

 

 

 

 

 

 

 

 

316

Measurement current correction

-10 ~ +10

default:

0

 

 

 

 

 

for APVC (corrects current

 

Enter the value recorded on the

 

measured at time of APVC)

 

label on the composite power

 

 

 

supply when replacing the

 

 

 

 

composite power supply.

 

 

 

 

 

 

 

 

 

 

 

317

Fluorescent lamp pre-heating

-9 ~ +9

default:

0

 

 

 

 

 

current adjustment

 

Enter the value recorded on the

 

 

 

label on the composite power

 

 

 

supply when replacing the

 

 

 

 

composite power supply.

 

 

 

 

 

 

318

Transfer output voltage

-4 ~ +4

Convert the value recorded on the

 

adjustment (corrects transfer

 

label on the composite power

 

voltage determined by ATVC)

 

supply as follows and change the

 

 

 

value recorded on the service label;

 

 

 

then, enter the value when replacing

 

 

 

the composite power supply.

 

 

 

 

Label

Input

Label

 

Input

 

 

 

1

0

6

+1

 

 

 

2

-1

7

+2

 

 

 

3

-2

8

+3

 

 

 

4

-3

9

+4

 

 

 

5

-4

 

 

 

 

 

 

 

319

Arch adjustment when

0 ~ 63

A higher setting increases the arch.

 

multifeeder is used (pick-up roller

 

default:

25

 

 

 

 

 

OFF timing)

 

unit:

0.27 mm

 

 

 

 

 

 

 

 

 

 

 

 

COPYRIGHT © 1997 CANON INC.

CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)

10-103

Page 367
Image 367
Canon FY8-13EX-000, NP6218 service manual 10-103