Canon NP6218, FY8-13EX-000 service manual 6-24

Models: FY8-13EX-000 NP6218

1 389
Download 389 pages 16.29 Kb
Page 190
Image 190
6-24

CHAPTER 6 FIXING SYSTEM

9. Detaching the Separation Claw/Lower Fixing Claw and Fixing Cleaning Roller

1)Detach the front door.

2)Remove the screw q, and detach the separation claw unit w.

e

Figure 6-224

3) Detach the separation claw e from the separation claw unit.

Caution:

Take care not to misplace the spring.

4) Detach the lower fixing roller r together with the bushing t.

er

Figure 6-225

6-24

COPYRIGHT © 1997 CANON INC.

CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)