Canon NP6218, FY8-13EX-000 Adjusting the Scanning Lamp Intensity, 10-10, positioning, Reference

Models: FY8-13EX-000 NP6218

1 389
Download 389 pages 16.29 Kb
Page 274
Image 274
positioning.

CHAPTER 10 TROUBLESHOOTING

The entire shutters are

Shutter 6. Adjusting the Scanning Lamp Intensity shifted.

Figure 10-209

Caution:

After the adjustments (both a and b), turn on and off the power switch or change

the reproduction ratio so that the blank exposure assembly performs home

positioning.

6. Adjusting the Scanning Lamp Intensity

Turn VR301 on the DC controller as follows whenever you have replaced the scanning lamp, intensity sensor, or DC controller.

1)Set Test Sheet NA3 on the copyboard, and close the copyboard cover.

2)Adjust the copy density (AE off) to electrical central position (service mode 1/0 mode [2] No. 212 Value = 153~159).

Without this adjustment, exposure value becomes invalid.

3)Turn VR301 on the DC controller so that the image is optimum.

If the image is too light, turn the VR slightly clockwise.

If the image is too dark, turn the VR slightly counterclockwise.

Reference:

1.The term optimum image refers to a copy whose gray scale No. 8 corresponds to gray scale No. 4 through 7 of the Test Sheet without fogging.

2.An excessive turn on the VR could put out the lamp. If that is the case, turn it clockwise until it stops, and turn off and then on the power for re-adjustment.

Caution:

Be sure to execute AE adjustment after these adjustments.