CHAPTER 3 EXPOSURE SYSTEM

C. Basic Sequence of Operations (lens drive system; non-Direct)

When a specific reproduction ratio is selected, the lens always returns to the home position before moving to the position appropriate to the selected ratio. This also holds true when the reproduction ratio is reset to Direct.

Power switch

Copy Start key

ON

ON

Scanner home position sensor (PS1)

Registration sensor (PS6)

Scanner

Scanning lamp

STBY

INTR

SCFW

SCRV

SCFW

SCRV

LSTR

 

 

AER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Forward Reverse

 

 

 

Half pre-heating

Full pre-

ON Pre-heating

 

 

Half pre-

 

heating

 

 

heating

 

*Unless it is at the home position already, the scanner returns to the home position at power-on.

Figure 3-203

3-4

COPYRIGHT © 1997 CANON INC.

CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)

Page 57
Image 57
Canon FY8-13EX-000, NP6218 Basic Sequence of Operations lens drive system non-Direct, Stby Intr Scfw Scrv Lstr AER