7)Loosen the two screws r to loosen the cable tension (both front and right). r

Figure 3-405

8)Move the No. 1 mirror mount to the front to align the long hole in the front side plate and the cable fixing screw t.

Then, detach the cable fixing screw t to separate the No. 1 mirror mount and the scanner cable (both front and rear).

t

(front)

t

(rear)

Figure 3-406