6. Adjusting the Left/Right Registration

CHAPTER 5 PICK-UP/FEEDING SYSTEM

3) Remove the two screws e, and detach the separation pad unit r.

Figure 5-712

6. Adjusting the Left/Right Registration

Make adjustments so that the position of the image is as shown in Figure 5-714 when the Test Sheet is copied in Direct.

a.Pick-Up from the Cassette

Turn the screw q shown in Figure 5-713 to adjust the position of the cassette hook

plate.

 

standard:

0 ±1.5 mm

clockwise turn:

moves the paper in the direction of – shown in Figure 5-714

counterclockwise turn: moves the paper in the direction of + shown in Figure 5-714

(-)

 

 

 

(+)

 

 

 

q

 

 

0±1.5mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

2

4

6

8

10

Figure 5-713

Figure 5-714

5-22

COPYRIGHT © 1997 CANON INC.