Chapter 4 Command Reference

gaintrig

gaintrig

To display the gain alarm trigger level, use the gaintrig command.

gaintrig

Syntax Description

Defaults

Command Types

Command Modes

Command History

This command has no other arguments or keywords.

None

Does not change configuration

User password protected

ReleaseModification

EDFA 1.0

This command was introduced.

 

 

Usage Guidelines

The value for Cisco ONS 15501 gain alarm trigger level is displayed in dB.

 

 

 

Examples

The following example shows how to display the gain alarm trigger level.

 

edfa > gaintrig

 

 

1.00 (dB)

 

 

 

 

 

Related Commands

 

Command

Description

 

 

 

 

 

 

gain

Displays the measured optical signal gain.

 

 

 

 

 

 

gainmean

Displays the configured signal gain and alarm mean level.

 

 

 

 

 

 

resetmeantrig

Resets the signal gain and alarm mean level, gain alarm trigger level, optical

 

 

 

input alarm mean level, optical input alarm trigger level, output signal alarm

 

 

 

mean level, output signal alarm trigger level, internal case temperature

 

 

 

alarm mean level, and internal case temperature alarm trigger level to the

 

 

 

manufacturer’s default settings.

 

 

 

 

 

 

setgainmean

Sets the signal gain and alarm mean level.

 

 

 

 

 

 

setgaintrig

Sets the gain alarm trigger level.

 

 

 

 

 

Cisco ONS 15501 User Guide

4-12

78-14134-02, Release 2.0

Page 52
Image 52
Cisco Systems 15501 manual Gaintrig