4-12
Cisco ONS 15501 User Guide
78-14134-02, Release 2.0
Chapter4 Command Reference
gaintrig
gaintrig
To display the gain alarm trigger level, use the gaintrig command.
gaintrig
Syntax Description
Defaults None
Command Types Does not change configuration
Command Modes User password protected
Command History
Usage Guidelines The value for CiscoONS 15501 gain alarm trigger level is displayed in dB.
Examples The following example shows how to display the gain alarm trigger level.
edfa > gaintrig
1.00 (dB)
Related Commands
This command has no other arguments or keywords.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
gain Displays the measured optical si gnal gain.
gainmean Displays the configured signal gain and alarm mean level.
resetmeantrig Resets the signal gain and alarm mea n level, gain alarm trigge r level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, inter nal case temperature
alarm mean level, and internal ca se temperature alarm trigger level to the
manufacturers default setting s.
setgainmean Sets the signal gain and alarm mean level.
setgaintrig Sets the gain alarm trigger level.