Chapter 4 Command Reference
setoutsigpwrmean
setoutsigpwrmean
To set the output signal alarm mean level, use the setoutsigpwrmean command.
setoutsigpwrmean mean
Syntax Description
Defaults
Command Types
Command Modes
mean | Specifies the desired output signal alarm mean level. |
|
|
2.00 dBm
Changes configuration
Master password protected
Command History | Release | Modification |
| EDFA 1.0 | This command was introduced. |
|
|
|
Usage Guidelines
Examples
The output signal alarm mean is measured in dBm. See Table
The following example shows how to set the output signal alarm mean level.
edfa > setoutsigpwrmean 1.00
Related Commands | Command | Description |
| outsigpwr | Displays the calculated output signal power. |
|
|
|
| outsigpwrmean | Displays the output signal alarm mean level. |
|
|
|
| outsigpwrtrig | Displays the output signal alarm trigger level. |
|
|
|
| resetmeantrig | Resets the signal gain and alarm mean level, gain alarm trigger level, optical |
|
| input alarm mean level, optical input alarm trigger level, output signal alarm |
|
| mean level, output signal alarm trigger level, internal case temperature |
|
| alarm mean level, and internal case temperature alarm trigger level to the |
|
| manufacturer’s default settings. |
|
|
|
| setoutsigpwrtrig | Sets the output signal alarm trigger level. |
|
|
|
|
| Cisco ONS 15501 User Guide |
|
| |
|
|
| |||
|
|
|
|
| |
|
|
|
|