Chapter 4 Command Reference
outsigpwr
outsigpwr
To display the calculated output signal power, use the outsigpwr command.
outsigpwr
Syntax Description
Defaults
Command Types
Command Modes
Command History
This command has no other arguments or keywords.
None
Does not change configuration
User password protected
ReleaseModification
EDFA 1.0 | This command was introduced. |
|
|
Usage Guidelines | The value for calculated output signal power is displayed in dBm. | ||
|
|
| |
Examples | The following example shows how to display the calculated output signal power. | ||
| edfa > outsigpwr |
| |
|
| ||
|
|
|
|
Related Commands |
| Command | Description |
|
|
|
|
|
| outsigpwrmean | Displays the output signal alarm mean level. |
|
|
|
|
|
| outsigpwrtrig | Displays the output signal alarm trigger level. |
|
|
|
|
|
| resetmeantrig | Resets the signal gain and alarm mean level, gain alarm trigger level, optical |
|
|
| input alarm mean level, optical input alarm trigger level, output signal alarm |
|
|
| mean level, output signal alarm trigger level, internal case temperature |
|
|
| alarm mean level, and internal case temperature alarm trigger level to the |
|
|
| manufacturer’s default settings. |
|
|
|
|
|
| setoutsigpwrmean | Sets the output signal alarm mean level. |
|
|
|
|
|
| setoutsigpwrtrig | Sets the output signal alarm trigger level. |
|
|
|
|
|
| Cisco ONS 15501 User Guide |
|
| |
|
|
| |||
|
|
|
|
| |
|
|
|
|