Cisco Systems 15501 manual Status, 29.53 C 25.10 C 29.90 C

Models: 15501

1 128
Download 128 pages 43.78 Kb
Page 93
Image 93

Chapter 4 Command Reference

status

status

To display the measured, alarm mean and alarm trigger values for input power, internal case temperature, optical gain and output signal power, as well as the measured values for optical output power, use the status command.

status

Syntax Description

Defaults

Command Types

Command Modes

Command History

This command has no other arguments or keywords.

None

Does not change configuration

User password protected

ReleaseModification

EDFA 1.0

This command was introduced.

 

 

Examples

The following example shows how to display the status of the system.

 

 

edfa > status

 

 

 

 

 

 

===============================================================================

 

 

Status

Measured

Mean

Trigger

 

Input Optical Power

NORMAL

-15.84 (dBm)

-10.00 (dBm)

15.00 (dBm)

 

Optical Gain

NORMAL

6.99 (dB)

7.00 (dB)

0.50 (dB)

 

Optical Output Power

 

-8.72

(dBm)

 

 

 

Output Signal Power

NORMAL

-8.77

(dBm)

-6.00 (dBm)

18.00 (dBm)

 

Power Supply 1

OUT-OF-RANGE

-3.48

(vDC)

 

 

 

Power Supply 2

NORMAL

-49.70

(vDC)

 

 

 

Pump Laser

GOOD

 

 

 

 

 

Temperature

NORMAL

29.53 (C)

25.10 (C)

29.90 (C)

 

===============================================================================

 

 

Cisco ONS 15501 User Guide

 

 

 

 

 

 

78-14134-02, Release 2.0

 

 

4-53

 

 

 

 

 

Page 93
Image 93
Cisco Systems 15501 manual Status, 29.53 C 25.10 C 29.90 C