Chapter 4 Command Reference
status
status
To display the measured, alarm mean and alarm trigger values for input power, internal case temperature, optical gain and output signal power, as well as the measured values for optical output power, use the status command.
status
Syntax Description
Defaults
Command Types
Command Modes
Command History
This command has no other arguments or keywords.
None
Does not change configuration
User password protected
ReleaseModification
EDFA 1.0 | This command was introduced. |
|
|
Examples | The following example shows how to display the status of the system. |
| ||||
| edfa > status |
|
|
|
|
|
| =============================================================================== | |||||
|
| Status | Measured | Mean | Trigger | |
| Input Optical Power | NORMAL | 15.00 (dBm) | |||
| Optical Gain | NORMAL | 6.99 (dB) | 7.00 (dB) | 0.50 (dB) | |
| Optical Output Power |
| (dBm) |
|
| |
| Output Signal Power | NORMAL | (dBm) | 18.00 (dBm) | ||
| Power Supply 1 | (vDC) |
|
| ||
| Power Supply 2 | NORMAL | (vDC) |
|
| |
| Pump Laser | GOOD |
|
|
|
|
| Temperature | NORMAL | 29.53 (C) | 25.10 (C) | 29.90 (C) | |
| =============================================================================== |
|
| Cisco ONS 15501 User Guide |
|
| |
|
|
| |||
|
|
|
|
| |
|
|
|
|