Chapter 4 Command Reference

setgainmean

setgainmean

To modify the signal gain and alarm mean, use the setgainmean command.

setgainmean mean

Syntax Description

Defaults

Command Types

Command Modes

mean

Specifies the desired signal gain and alarm mean.

 

 

17.5 dB

Changes configuration

Master password protected

Command History

Release

Modification

 

EDFA 1.0

This command was introduced.

 

 

 

Usage Guidelines

Examples

The signal gain and alarm mean is measured in dB. The system accepts a minimum value of 7 dB and a maximum value of 17.5 dB. If a value entered falls outside of this acceptable range, the command will be ignored and have no effect.

The following example shows how to modify the signal gain and alarm mean.

edfa > setgainmean 17.00

Related Commands

Command

Description

 

gain

Displays the measured optical signal gain.

 

 

 

 

gainmean

Displays the configured signal gain and alarm mean level.

 

 

 

 

gaintrig

Displays the gain alarm trigger level.

 

 

 

 

resetmeantrig

Resets the signal gain and alarm mean level, gain alarm trigger level, optical

 

 

input alarm mean level, optical input alarm trigger level, output signal alarm

 

 

mean level, output signal alarm trigger level, internal case temperature

 

 

alarm mean level, and internal case temperature alarm trigger level to the

 

 

manufacturer’s default settings.

 

 

 

 

setgaintrig

Sets the gain alarm trigger level.

 

 

 

 

Cisco ONS 15501 User Guide

4-40

78-14134-02, Release 2.0

Page 80
Image 80
Cisco Systems 15501 manual Setgainmean, Syntax Description Defaults Command Types Command Modes