Chapter 4 Command Reference
tempmean
tempmean
Syntax Description
Defaults
Command Types
Command Modes
Command History
To display the internal case temperature alarm mean level, use the tempmean command.
tempmean
This command has no other arguments or keywords.
None
Does not change configuration
User password protected
ReleaseModification
EDFA 1.0 | This command was introduced. |
|
|
Examples | The following example shows how to display the internal case temperature alarm mean level. | ||
| edfa > tempmean |
| |
| 29.00 (C) |
| |
|
|
|
|
Related Commands |
| Command | Description |
|
|
|
|
|
| resetmeantrig | Resets the signal gain and alarm mean level, gain alarm trigger level, optical |
|
|
| input alarm mean level, optical input alarm trigger level, output signal alarm |
|
|
| mean level, output signal alarm trigger level, internal case temperature |
|
|
| alarm mean level, and internal case temperature alarm trigger level to the |
|
|
| manufacturer’s default settings. |
|
|
|
|
|
| settempmean | Sets the internal case temperature alarm mean level. |
|
|
|
|
|
| settemptrig | Sets the internal case temperature alarm trigger level. |
|
|
|
|
|
| temp | Displays the internal case temperature level. |
|
|
|
|
|
| temptrig | Displays the internal case temperature alarm trigger level. |
|
|
|
|
| Cisco ONS 15501 User Guide |
|