To display the output signal alarm mean level, use the outsigpwrmean command.
outsigpwrmean
This command has no other arguments or keywords.
None
Does not change configuration
User password protected
ReleaseModification
EDFA 1.0 | This command was introduced. |
|
|
Usage Guidelines | The value for output signal alarm mean level is displayed in dBm. | ||
|
|
| |
Examples | The following example shows how to display the output signal alarm mean level. | ||
| edfa > outsigpwrmean |
| |
| 2.00 (dBm) |
| |
|
|
|
|
Related Commands |
| Command | Description |
|
|
|
|
|
| outsigpwr | Displays the calculated output signal power. |
|
|
|
|
|
| outsigpwrtrig | Displays the output signal alarm trigger level. |
|
|
|
|
|
| resetmeantrig | Resets the signal gain and alarm mean level, gain alarm trigger level, optical |
|
|
| input alarm mean level, optical input alarm trigger level, output signal alarm |
|
|
| mean level, output signal alarm trigger level, internal case temperature |
|
|
| alarm mean level, and internal case temperature alarm trigger level to the |
|
|
| manufacturer’s default settings. |
|
|
|
|
|
| setoutsigpwrmean | Sets the output signal alarm mean level. |
|
|
|
|
|
| setoutsigpwrtrig | Sets the output signal alarm trigger level. |
|
|
|
|