4-43
Cisco ONS 15501 User Guide
78-14134-02, Release 2.0
Chapter4 Command Reference
setinpwrtrig
setinpwrtrig
To set the optical input alarm trig ger level, use the setinpwrtrig command.
setinpwrtrig trigger
Syntax Description
Defaults 10.00 dBm
Command Types Changes configuration
Command Modes Master password protecte d
Command History
Usage Guidelines The optical input alarm trigger is measured in dB. See Table1-2 on page 1-2 for the minimum and
maximum values. If a value enter ed falls outside of this acce ptable range, the command will be ignored
and have no effect.
Examples The following example shows how to set th e optical input alarm trigger level.
edfa > setinpwrtrig 2.00
Related Commands
trigger Specifies the desir ed optical input alarm tr igger level.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
inpwr Displays the measured optical input power.
inpwrmean Displays the optical input alarm mean level.
inpwrtrig Displays the optical input alarm trigger level.
resetmeantrig Resets the signal gain and alarm mea n level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, inter nal case temperature
alarm mean level, and internal ca se temperature alarm trigger level to the
manufacturers default setting s.
setinpwrmean Sets the optical input alarm mean level.