4-48
Cisco ONS 15501 User Guide
78-14134-02, Release 2.0
Chapter4 Command Reference
settemptrig
settemptrig
To set the internal case temperature alarm trigger level, use the settemptrig command.
settemptrig trigger
Syntax Description
Defaults 30° C
Command Types Changes configuration
Command Modes Master password protecte d
Command History
Usage Guidelines The internal case temperature trigger is measured in degree s Celsius. See Table 1-2 on page1-2. for the
minimum and maximum values. If a value entered falls outside o f this acceptable range, the co mmand
will be ignored and have no effect.
Examples The following example shows how to set the internal case temperature alarm trigger level.
edfa > settemptrig 29.00
Related Commands
trigger Specifies the desired internal case temperature alarm trigger level.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
resetmeantrig Resets the signal gain and alarm mea n level, gain alarm trigge r level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, inter nal case temperature
alarm mean level, and internal ca se temperature alarm trigger level to the
manufacturers default setting s.
settempmean Sets the internal case temperature a larm mean level.
temp Displays the internal case temperature level.
tempmean Displays the internal case tempera ture alarm mean level.
temptrig Displays the internal case temperature alarm trigger level.