Chapter 4 Command Reference

settemptrig

settemptrig

To set the internal case temperature alarm trigger level, use the settemptrig command.

settemptrig trigger

Syntax Description

Defaults

Command Types

Command Modes

trigger

Specifies the desired internal case temperature alarm trigger level.

 

 

30° C

Changes configuration

Master password protected

Command History

Release

Modification

 

EDFA 1.0

This command was introduced.

 

 

 

Usage Guidelines

Examples

The internal case temperature trigger is measured in degrees Celsius. See Table 1-2 on page 1-2. for the minimum and maximum values. If a value entered falls outside of this acceptable range, the command will be ignored and have no effect.

The following example shows how to set the internal case temperature alarm trigger level.

edfa > settemptrig 29.00

Related Commands

Command

Description

 

resetmeantrig

Resets the signal gain and alarm mean level, gain alarm trigger level, optical

 

 

input alarm mean level, optical input alarm trigger level, output signal alarm

 

 

mean level, output signal alarm trigger level, internal case temperature

 

 

alarm mean level, and internal case temperature alarm trigger level to the

 

 

manufacturer’s default settings.

 

 

 

 

settempmean

Sets the internal case temperature alarm mean level.

 

 

 

 

temp

Displays the internal case temperature level.

 

 

 

 

tempmean

Displays the internal case temperature alarm mean level.

 

 

 

 

temptrig

Displays the internal case temperature alarm trigger level.

 

 

 

 

Cisco ONS 15501 User Guide

4-48

78-14134-02, Release 2.0

Page 88
Image 88
Cisco Systems 15501 manual Settemptrig, Settempmean