4-11
Cisco ONS 15501 User Guide
78-14134-02, Release 2.0
Chapter4 Command Reference
gainmean
gainmean
To display the configured signal gain and alarm mean level, use the gainmean command.
gainmean
Syntax Description
Defaults None
Command Types Does not change configuration
Command Modes User password protected
Command History
Usage Guidelines The value for configured Cisco ONS 155 01 signal gain and ala rm mean level is displaye d in dB.
Examples The following example shows how to display the configured signal gain and alarm mean level.
edfa > gainmean
17.50 (dB)
Related Commands
This command has no other arguments or keywords.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
gain Displays the measured optical si gnal gain.
gaintrig Displays the gain alarm trigger level.
resetmeantrig Resets the signal gain and alarm mea n level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, inter nal case temperature
alarm mean level, and internal ca se temperature alarm trigger level to the
manufacturers default setting s.
setgainmean Sets the signal gain and alarm mean level.
setgaintrig Sets the gain alarm trigger level.