resetmeantrig

resetmeantrig

 

 

 

 

To reset the alarm mean and trigger levels for signal gain, optical input power, output signal power, and

 

 

 

 

internal case temperature to the manufacturer’s default settings, use the resetmeantrig command.

 

 

 

 

 

resetmeantrig

 

 

 

 

 

 

 

Syntax Description

 

This command has no other arguments or keywords.

 

 

 

 

 

 

Defaults

None

 

 

 

 

 

 

 

 

 

Command Types

Changes configuration

 

 

 

 

 

 

 

Command Modes

Master password protected

 

 

 

 

 

Command History

 

Release

Modification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDFA 1.0

This command was introduced.

 

 

 

 

 

 

 

 

 

 

 

 

 

Usage Guidelines

The manufacturer’s default setting can be found in Table 1-2 on page 1-2.

 

 

 

 

 

Related Commands

 

Command

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gainmean

Displays the configured signal gain and alarm mean level.

 

 

 

 

 

 

 

 

 

 

 

 

 

gaintrig

Displays the gain alarm trigger level.

 

 

 

 

 

 

 

 

 

 

 

 

 

inpwrmean

Displays the optical input alarm mean level.

 

 

 

 

 

 

 

 

 

 

 

 

 

inpwrtrig

Displays the optical input alarm trigger level.

 

 

 

 

 

 

 

 

 

 

 

 

 

outsigpwrmean

Displays the output signal alarm mean level.

 

 

 

 

 

 

 

 

 

 

 

 

 

outsigpwrtrig

Displays the output signal alarm trigger level.

 

 

 

 

 

 

 

 

 

 

 

 

 

setgainmean

Sets the signal gain and alarm mean level.

 

 

 

 

 

 

 

 

 

 

 

 

 

setgaintrig

Sets the gain alarm trigger level.

 

 

 

 

 

 

 

 

 

 

 

 

 

setoutsigpwrmean

Sets the output signal alarm mean level.

 

 

 

 

 

 

 

 

 

 

 

 

 

setoutsigpwrtrig

Sets the output signal alarm trigger level.

 

 

 

 

 

 

 

 

 

 

 

 

 

setinpwrtrig

Sets the optical input alarm trigger level.

 

 

 

 

 

 

 

 

 

 

 

 

 

settempmean

Sets the internal case temperature alarm mean level.

 

 

 

 

 

 

 

 

 

 

 

 

 

settemptrig

Sets the internal case temperature alarm trigger level.

 

 

 

 

 

 

 

 

 

 

 

 

 

tempmean

Displays the internal case temperature alarm mean level.

 

 

 

 

 

 

 

 

 

 

 

 

 

temptrig

Displays the internal case temperature alarm trigger level.

 

 

 

 

 

 

 

 

 

 

 