Chapter 4 Command Reference

temp

temp

To display the internal case temperature, use the temp command.

temp

Syntax Description

Defaults

Command Types

Command Modes

Command History

This command has no other arguments or keywords.

None

Does not change configuration

User password protected

ReleaseModification

EDFA 1.0

This command was introduced.

 

 

Examples

The following example shows how to display the internal case temperature.

 

edfa > temp

 

 

85.28 (C)

 

 

 

 

 

Related Commands

 

Command

Description

 

 

 

 

 

 

resetmeantrig

Resets the signal gain and alarm mean level, gain alarm trigger level, optical

 

 

 

input alarm mean level, optical input alarm trigger level, output signal alarm

 

 

 

mean level, output signal alarm trigger level, internal case temperature

 

 

 

alarm mean level, and internal case temperature alarm trigger level to the

 

 

 

manufacturer’s default settings.

 

 

 

 

 

 

settempmean

Sets the internal case temperature alarm mean level.

 

 

 

 

 

 

settemptrig

Sets the internal case temperature alarm trigger level.

 

 

 

 

 

 

tempmean

Displays the internal case temperature alarm mean level.

 

 

 

 

 

 

temptrig

Displays the internal case temperature alarm trigger level.

 

 

 

 

 

 

Cisco ONS 15501 User Guide

 

 

 

 

 

 

78-14134-02, Release 2.0

 

 

4-57

 

 

 

 

 

Page 97
Image 97
Cisco Systems 15501 manual Temp, Command Description