Chapter 4 Command Reference

outsigpwrtrig

outsigpwrtrig

Syntax Description

Defaults

Command Types

Command Modes

Command History

To display the output signal alarm trigger level, use the outsigpwrtrig command.

outsigpwrtrig

This command has no other arguments or keywords.

None

Does not change configuration

User password protected

ReleaseModification

EDFA 1.0

This command was introduced.

 

 

Usage Guidelines

The value for output signal alarm trigger level is displayed in dBm.

 

 

 

Examples

The following example shows how to display the output signal alarm trigger level.

 

edfa > outsigpwrtrig

 

 

20.00 (dBm)

 

 

 

 

 

Related Commands

 

Command

Description

 

 

 

 

 

 

outsigpwr

Displays the calculated output signal power.

 

 

 

 

 

 

outsigpwrmean

Displays the output signal alarm mean level.

 

 

 

 

 

 

resetmeantrig

Resets the signal gain and alarm mean level, gain alarm trigger level, optical

 

 

 

input alarm mean level, optical input alarm trigger level, output signal alarm

 

 

 

mean level, output signal alarm trigger level, internal case temperature

 

 

 

alarm mean level, and internal case temperature alarm trigger level to the

 

 

 

manufacturer’s default settings.

 

 

 

 

 

 

setoutsigpwrmean

Sets the output signal alarm mean level.

 

 

 

 

 

 

setoutsigpwrtrig

Sets the output signal alarm trigger level.

 

 

 

 

 

 

Cisco ONS 15501 User Guide

 

 

 

 

 

 

78-14134-02, Release 2.0

 

 

4-33

 

 

 

 

 

Page 73
Image 73
Cisco Systems 15501 manual Outsigpwrtrig