Chapter 4 Command Reference
setgaintrig
setgaintrig
To modify the signal gain alarm trigger level, use the setgaintrig command.
setgaintrig trigger
Syntax Description
Defaults
Command Types
Command Modes
trigger | Specifies the desired signal gain and alarm trigger. |
|
|
1.00 dB
Changes configuration
Master password protected
Command History | Release | Modification |
| EDFA 1.0 | This command was introduced. |
|
|
|
Usage Guidelines
Examples
The signal gain alarm trigger level is measured in dB. See Table
The following example shows how to modify the gain alarm trigger level.
edfa > setgaintrig 2.00
Related Commands | Command | Description |
| gain | Displays the measured optical signal gain. |
|
|
|
| gainmean | Displays the configured signal gain and alarm mean level. |
|
|
|
| gaintrig | Displays the gain alarm trigger level. |
|
|
|
| resetmeantrig | Resets the signal gain and alarm mean level, gain alarm trigger level, optical |
|
| input alarm mean level, optical input alarm trigger level, output signal alarm |
|
| mean level, output signal alarm trigger level, internal case temperature |
|
| alarm mean level, and internal case temperature alarm trigger level to the |
|
| manufacturer’s default settings. |
|
|
|
| setgainmean | Sets the signal gain and alarm mean level. |
|
|
|
|
| Cisco ONS 15501 User Guide |
|
| |
|
|
| |||
|
|
|
|
| |
|
|
|
|