setinpwrmean
setinpwrmean
To set the optical input alarm mean level, use the setinpwrmean command.
setinpwrmean mean
Syntax Description
Defaults 20.00 dBm
Command Types Changes configuration
Command Modes Master password protecte d
Command History
Usage Guidelines The optical input alarm mean is measured in dBm. See Table1-2 on page 1-2 for the minimum and
maximum values. If a value enter ed falls outside of this acce ptable range, the command will be ignored
and have no effect.
Examples The following example shows how to set th e optical input alarm mean level.
edfa > setinpwrmean -28.00
Related Commands
mean Specifies the desired optic al input alarm mean level.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
inpwr Displays the measured optical input power.
inpwrmean Displays the optical input alarm mean level.
inpwrtrig Displays the optical input alarm trigger level.
resetmeantrig Resets the signal gain and alarm mea n level, gain alarm trigge r level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, inter nal case temperature
alarm mean level, and internal ca se temperature alarm trigger level to the
manufacturers default setting s.
setinpwrtrig Sets the optical input alarm trigger level.