3-103
Cisco Signaling Gateway Manager User Guide
78-15589-01
Chapter3 Managing ITP Networks Using SGM
Working with Nodes
•Status—Current status of the linkset. Possible values are:
–
Active (green ball)—The linkset is currently fully functional.
–
Unavailable (red ball)—An error is preventing traffic from flowing on
this linkset.
–
Shutdown (blue ball)—An ITP administrator has set the linkset to
prevent traffic from flowing. When a linkset is set to Shutdown, all its
associated links are set to Failed by Cisco I OS.
–
Unknown (red ball)—Either the node associated with this linkset has
failed to respond to an SNMP request, or SGM found that the linkset no
longer exists.
–
Warning (yellow ball)—The linkset is active, but one or more links in
the linkset is congested or is in Failed, Unknown, or Warn ing status,
and is not Ignored. At least one link is available and can carry traffic.
•Status Reason—Reason for the current status of the linkset. Possible values
are:
–
None
–
SGM Restart
–
Unsupported Configuration
–
Unconfigured
–
SNMP Timeout
–
Device is unreachable, possibly wrong community string
–
Not ITP Device
–
Not Configured for ITP
–
MIB Data Error
–
SNMP Exception
–
SignalingPoint Inactive
–
Linkset Inactive
–
Link Congested
–
Link Send Utilization Threshold Exceeded
–
Link Receive Utilization Threshold Exceeded
–
Link Local Interface Inactive