Technical Specifications

This appendix provides the technical specification for the Cisco IE 2000 switches.

Operating Temperature Specifications

Table A-1lists the operating temperatures for the Cisco IE 2000 switches in three different environments.

Table A-1

Operating Temperature for the Cisco IE 2000 Switches

 

 

 

 

 

 

Industrial Automation and

 

 

 

Hazardous Locations

Substation

Traffic Signal

 

 

 

 

Enclosure

Sealed enclosures

Vented enclosures

Fan or blower-equipped

types

For example: NEMA4, NEMA4X,

For example: NEMA1, IP20, and

enclosures

 

 

 

NEMA12, NEMA13, IP54, and

IP21.

For example: NEMA TS-2.

 

IP66.

 

Note The minimum airflow is

 

 

 

 

 

 

150 lfm1.

Operating

–40 to 140°F (–40 to 60°C)

–40 to 158°F (–40 to 70°C)

–29 to 167°F (–34 to 75°C)

temperature2

 

 

 

1.lfm = linear feet per minute.

2.Operating temperature ranges provided are based on the stated NEMA standards. The switch is test verified for operation to -40°F/40°C. There is no safety coverage outside of these parameters.

Note The safety certifications apply only to ambient temperatures under 140°F (60°C). However, the Cisco IE 2000 switch can function in the substation and traffic signal installations under the environmental conditions shown in Table A-1.