Chapter 2 Switch Installation

Connecting Alarm Circuits

Figure 2-21 Removing the Alarm Connector

.5-3.0A

16TC

332048

1

1

Alarm connector

Step 2 Measure two strands of twisted-pair wire (18-to-20 AWG) long enough to connect to the external alarm device. Choose between setting up an external alarm input or output circuit.

Step 3 Use a wire stripper to remove the casing from both ends of each wire to 0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm). Do not strip more than 0.27 inch (6.8 mm) of insulation from the wires. Stripping more than the recommended amount of wire can leave exposed wire from the alarm connector after installation.

Step 4 Insert the exposed wires for the external alarm device into the connections based on an alarm input or output circuit setup (see Table 2-3). For example, to wire an alarm input circuit, complete the IN1 and REF connections (See Figure 2-22).

 

Cisco IE 2000 Switch Hardware Installation Guide

2-36

OL-25818-04

Page 66
Image 66
Cisco Systems IE20004TSB, IE20004TSL, IE200016TCB manual Removing the Alarm Connector